www.r-techwelding.co.uk email: [email protected] Tel: 01452 733933 Fax 01452 733939 TIG160PDC DC TIG
10 Connections for STICK MMA (SMAW) Welding Fig 3 1. Negative power connector - Connect the earth lead to by inserting and twisting until t
11 Controls and settings Fig 4 1. Up slope Adjustment 0-5 seconds. The main welding current raises from minimum amperage to main current selec
12 7. Pulse On/Off switch This turns the pulse welding on and off. 8. 2/4 Way selector switch 2/4 Step trigger mode switch – tig welding can eit
13 Press and hold the tig torch switch to start sequence. The machine will open gas valve to start flow of shield gas, after a 0.5 seconds pre-flow
14 Operating machine SAFETY PRECAUTIONS WARNING! ELECTRIC SHOCK CAN KILL Do not touch electrically live parts or electrode with skin or wet c
15 Welding in TIG mode – No Pulse 1. Connect the Tig Torch to machine, connect earth lead to machine & work piece. 2. Set the TIG/MMA switch t
16 Welding in STICK MMA (SMAW) Mode 1. Fit MMA electrode holder to machine 2. Fit earth lead to machine and to work piece 3. Select MMA on MMA/TI
17 Maintenance Routine and periodic maintenance WARNING! ELECTRIC SHOCK CAN KILL Turn the input power OFF at the mains switch & fuse box
18 Tig welding problems • No output - Power light is not lit Check machine on/off switch is in the ‘on’ position Check Input power to machine Che
19 • Poor weld penetration Check condition of earth lead and clamp and ensure clamp is connection via a clean area on work piece Check condition o
20 4 Gas flow may be insufficient, increase gas flow, reduce tungsten stick out from ceramic • No HF when torch trigger pressed, no blue spark bet
22
23
Thank you for selecting the R-Tech Tig160PDC Inverter DC Tig Welder. The Tig160PDC has many benefits over traditional TIG welders, including pulse w
4 Introduction The R-Tech Tig160PDC is a member of our field acclaimed family of welding products. Premium features include:- 1. Inverter power so
5 Safety Precautions Read entire section before starting installation WARNING! Electric Shock can kill – Only qualified personnel should perfo
6 Electrical Installation WARNING! ELECTRIC SHOCK CAN KILL Machine grounding and High Frequency Interference Protection This welder must be
7 Input Connections Make sure the voltage, phase and frequency of input power is as specified on machine rating plate located at rear of machine.
8 Connections for Tig160PDC Rear machine connections Fig 1 1. Mains input cable Fit required plug as per your electrical installation 2. O
9 Connections for TIG (GTAW) Welding Fig 2 1. Negative power connector - Connect Tig Torch Dinze to power connector by inserting and twistin
Commenti su questo manuale