R-Tech PLASMA 60HF Manuale di Riparazione

Navigare online o scaricare Manuale di Riparazione per Sistemi per la saldatura R-Tech PLASMA 60HF. R-Tech PLASMA 60HF Repair manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
inverter
SUPERIOR PLASMA 90 HF
Cod.988343
“reparation no-problem”
TROUBLESHOOTING
AND REPAIR MANUAL
TROUBLESHOOTING
AND
REPAIR MANUAL
TROUBLESHOOTING
AND REPAIR MANUAL
TROUBLESHOOTING
AND REPAIR MANUAL
CONTENTS PAGE
OPERATION AND WIRING DIAGRAMS.........................2
REPAIR GUIDE..............................................................12
SPARE PARTS LIST...................................................... 24
REPAIRING CARD........................................................ 27
Block diagram 2
Analysis of block diagram 3
Illustrations 5
Wiring diagrams 7
Equipment required 12
General repair instructions 13
Troubleshooting and remedies 13
Testing the machine 17
Illustrations 20
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - SUPERIOR PLASMA 90 HF

inverterSUPERIOR PLASMA 90 HFCod.988343“reparation no-problem”TROUBLESHOOTINGAND REPAIR MANUALTROUBLESHOOTINGANDREPAIR MANUALTROUBLESHOOTINGAND REPAIR

Pagina 2

SUPERIOR PLASMA 90 HFWiring diagram control board - DWiring diagram control board - C10

Pagina 3

SUPERIOR PLASMA 90 HF11Wiring diagram auxiliary controlWiring diagram HF filter boardWiring diagram HF filter boardWiring diagram secondary board

Pagina 4

ESSENTIAL INSTRUMENTSUSEFUL INSTRUMENTSMISCELLANEOUS1 Dual trace oscilloscope 802401 (*)2 Static load generator 802111 (*)3 Variac 0 - 500V 4500VA 802

Pagina 5

WARNING:WARNINGBEFORE PROCEEDING WITH REPAIRS TO THEMACHINE READ THE INSTRUCTION MANUALCAREFULLY.EXTRAORDINARY MAINTENANCE OPERATIONSSHOULD BE CARRIED

Pagina 6

14Air inlet fan fastened to the back (fig. 2B)Primary board (fig. 6):Auxiliary power supply board (fig. 3)Auxiliary transformer (fig. 3)Secondary boar

Pagina 7

transformer (E ALTOand C BASSO);the connections of the auxiliary transformer and to theauxiliaryboard;the connections of the armoured resistors R1 and

Pagina 8

- repeat this test with the differential probe connected betweenresistor R20 (rheofore towards D10) and the earth on the cathodeof diode D11 (check bo

Pagina 9

B) Removing the secondary board (fig. 5)C) Replacing the control board (fig. 2A)1.1 Preparation for testing1.2 Scheduled testsUnless the dissipator ha

Pagina 10

- if the output current on the load is not 90A, adjust it usingR55 on the control board ( )- disable the ohmic loads and switch off the machine at the

Pagina 11

G) Checkingtorchoperation (fig.K)a)b)H) CheckingHF operation(fig.4)I) Cutting testIf the load test was positive but arc strike is difficult or evenimp

Pagina 12 - REPAIR GUIDEREPAIR GUIDE

SUPERIOR PLASMA 90 HFBLOCK DIAGRAMOPERATION AND WIRING DIAGRAMSOPERATION AND WIRING DIAGRAMSOPERATION AND WIRING DIAGRAMSOPERATION AND WIRING DIAGRAMS

Pagina 13

ILLUSTRATIONSSCREWSSCREWSCREWSTOP COVERSCREWS BOTTOMSCREWS20SUPERIOR PLASMA 90 HFSCREWSCREWSSCREWS

Pagina 14

RED LEDFOR GENERALALARMYELLOW LEDFOR TORCH VOLTAGEGREEN LEDFOR POWER SUPPLYYELLOE LEDFOR PHASE FAILURECURRENTPOTENTIOMETERSWITCH POST-AIRBACK FANCONNE

Pagina 15 - FIGURA C

POWERTRANSFORMERINDUCTANCEKITCONTROLBOARDAUXILIARYTRANSFORMERPRIMARY BOARDPOWER SUPPLYAUXILIARY BOARDHALLSENSORSECONDARY BOARDBOTTOMAUXILIARY CONTROL

Pagina 16 - FIGURE E

23SENSORHALLC1C5C4C2 C1A C4AC2AC5AK1K2D3D2D1K3BOTTOMKITHFTRANSFORMERSECONDARYSNUBBERSECONDARY BOARDSECONDARYTHERMOSTATDIODESD5, D4, D3DIODES D1, D2PAN

Pagina 17 - FIGURE F

24SUPERIOR PLASMA 90 HF3639373842154124533354017211310684734202544242330323154431992226114671181612282948ELENCO PEZZI DI RICAMBIO - LISTE PIECES DETAC

Pagina 18

25SUPERIOR PLASMA 90 HFELENCO PEZZI DI RICAMBIOPIECES DETACHEESSPARE PARTS LISTERSATZTEILLISTEPIEZAS DE REPUESTOELENCO PEZZI DI RICAMBIOPIECES DETACHE

Pagina 19

26SUPERIOR PLASMA 90 HFEsploso torcia, Dessin torche, Torch drawing, Schlauchpaket - Explosionszeichnung, Diseño seccionado antorcha.ELENCO PEZZI RICA

Pagina 20 - ILLUSTRATIONS

27SUPERIOR PLASMA 90 HFOfficial servicing centersRepairing cardDate:Inverter :Serial number:Company:Technician:modelIn which place has the inverter be

Pagina 21

TELWIN S.p.A. - Via della Tecnica, 336030 VILLAVERLA (Vicenza) ItalyTel. +39 - 0445 - 858811Fax +39 - 0445 - 858800 / 858801E-mail: [email protected]

Pagina 22

3ANALYSIS OF THE BLOCK DIAGRAMNOTE: Unless indicated otherwise, it should be assumed thatthe components are assembled on the primary board ormachine.:

Pagina 23 - CONTROL BOARD

4Block 18Block 19Block 20Block 21Block 22Block 23Block 24Block 25Block 26Block 27Block 28Block 29Block 30Block 31Block 32Block 33Alarm blockMicrocontr

Pagina 24 - PIEZAS DE REPUESTO

Block 35Block 36Block 37Block 38Block 39Block 40Block 41HF safeguardTorch buttonPilot arc activationHF filterSolenoid valve 1,Solenoid valve 2 and hf

Pagina 25

6SUPERIOR PLASMA 90 HF(18)ALARM BLOCK(20)HALL SENSOR AMPLIFIERSControl board(9) DIODESECONDARYSecondary board(24) SECONDARYDIODE THERMOSTAT(17)ADDER(1

Pagina 26

SUPERIOR PLASMA 90 HF7General wiring diagramWIRING DIAGRAMSWiring diagram input filter board

Pagina 27 - Repairing card

SUPERIOR PLASMA 90 HF8Wiring diagram primary board - powerWiring diagram primary board - driver

Pagina 28 - CERTIFIED QUALITY SYSTEM

SUPERIOR PLASMA 90 HFWiring diagram control board - BWiring diagram control board - A9